CARBOTEC TR-PT, Centec Vietnam

Centec Vietnam
Trần Văn Ý | Mr. |
Sales Engineer I
========================
cellphone I          +84 989 199 111
                                +84 916 152 811

email I                  vany@pitesco.com
                                vany.pitesco@gmail.com

Skype I                 ytranht 

CARBOTEC TR-PT

Application

CARBOTEC TR-PT is a very precise carbon dioxide sensor for measurement of CO2 in beer and beer-based mixed drinks. Dissolved COhas a major impact on the quality and taste of the product.

Description

For continuous measurement of dissolved carbon dioxide in liquids, CARBOTEC TR-PT is perfectly suited. The instrument is designed for applications requiring maximum sensitivity and highest accuracy. It is easy to operate and maintain. For measuring carbon dioxide, the carbonated liquid flows through the sensor head (measurement chamber). Several times per minute the chamber is closed and its volume rapidly increases. This expansion generates a gas phase in the chamber. The large partial pressure difference of CO2 forces the carbon dioxide out of the sample (liquid in the chamber) into the gas phase. This fundamental scientific principle is described by Henry’s Law. Within seconds pressure equilibrium in the measurement chamber is reached. The equilibrium pressure corresponds to the content of CO2 in the sample. The CO2 content is determined by pressure and temperature measurement in the chamber. Any temperature drifts of the measured signal are automatically compensated for by an internal Pt100 sensor. After each measurement the sample is completely returned to the product without any loss.
  • Proven technology based on pressure-temperature measurement
  • Highly precise and fast determination of dissolved carbon dioxide
  • Several short measurement cycles per minute
  • Various flange connections available
  • Hygienic execution and full CIP capability

Technical Data

Measuring Range0 - 10 g/l
Accuracy± 0,05 g/l
Repeatability± 0,01 g/l
Response Time≤ 20 s
Pressure of Operationmax. 10 bar
Temperature of Operation- 10 - + 100 °C
Temperature SensorPt100
Material1.4404/AISI 316L, EPDM (FDA), PTFE (FDA)
Connectionscompatible to Varivent© inline-housings DN65 - DN150; others on request
Input6 x digital (24 VDC)
Output3 x digital (24 VDC) & 2 x analog (4 - 20 mA)
Profibus DPoption
Enclosure RatingIP65
Power Supply24 VDC